AHMEDABAD, INDIA · ISO 9001 : 2015 · ISO 14001 : 2015 · ISO 45001 : 2018
LIFELINE OF EVERY INDUSTRY
Product
Catalogue
2026
Precision-engineered stainless-steel flexible flow solutions for the world's most demanding process industries — designed, manufactured & certified at our Ahmedabad works.
Essem Works Pvt. Ltd. manufactures precision stainless steel flexible flow solutions from its works in Ahmedabad, Gujarat, India. We supply SS corrugated hoses, interlock hoses, and bellows & expansion joints to industries including chemical, oil & gas, power generation, pharmaceutical, food & beverage, and process engineering worldwide.
Supported by experienced engineers and advanced manufacturing infrastructure, Essem Works combines technical expertise with consultative service — delivering standard and fully custom solutions from DN6 to DN3000. Every product is manufactured to international standards, 100% pressure-tested in-house, and fully traceable from raw material mill certificate to dispatch documentation.
— MANUFACTURING CAPABILITY —
Corrugated hose range
DN6 (¼") to DN350 (14") — Mechanically Formed DN6–DN50 · Hydroformed DN20–DN300
Interlock hose range
DN6 to DN200 — Double Interlock, Loose Interlock, Polygonal (larger sizes on request)
Bellows & expansion joints
DN50 to DN3000 — single, universal, hinged, gimbal, pressure-balanced
Standard materials
SS 304L / 316L held in stock — SS 321 to order
Design standards
ISO 10380 · EJMA (11th Ed.) · EN 14917:2021
In-house testing
100% pneumatic leak test on every assembly; hydrostatic (1.5× working pressure), burst & fatigue-cycle testing to customer requirement
FACILITY
32,000 sq.ft.
Built-up works, Moraiya, Ahmedabad
SIZE RANGE
DN6 to DN3000
Instrument line to 3 m bellows
PRODUCT FAMILIES
3
Corrugated · interlock · bellows
CERTIFIED
ISO 9001 · 14001 · 45001
TÜV Rheinland
From a 6 mm instrument line to a 3 m bellows — every assembly leaves pneumatically tested.
Essem Works operates an integrated management system independently audited and certified by TÜV Rheinland. Manufacturing, environmental and occupational-health practices are reviewed annually against the latest international standards.
QUALITY MANAGEMENT
ISO 9001
: 2015
Certified by TÜV Rheinland · Cert. No. 01 100 2437759
ENVIRONMENTAL
ISO 14001
: 2015
Certified by TÜV Rheinland · Cert. No. 01 104 2537285
HEALTH & SAFETY
ISO 45001
: 2018
Certified by TÜV Rheinland · Cert. No. 01 213 2537285
ISO 9001 · 14001 · 45001 — TÜV Rheinland. The three scopes differ; we set them out exactly → essemworks.com/quality.html
— DESIGN & BUILD CODES —
■EJMA (11th Ed.) — Expansion Joint Manufacturers Association Standards
■EN 14917:2021 — metal bellows expansion joints for pressure applications
■ISO 10380 — corrugated metal hose & assemblies (pipework)
— TEST & INSPECTION —
Test
Scope
Hydrostatic test
1.5× working pressure — to customer requirement
Pneumatic / leak test
100% of every assembly / hose
Burst test
Destructive test for new designs
Fatigue cycle
For engineered bellows configurations
NDT on request
RT · UT · PT · helium leak
Third-party inspection
Third-party witness inspection on request
DOCUMENTATION AVAILABLE WITH EVERY SHIPMENT
Mill test certificates (EN 10204 3.1) · dimensional inspection report · pneumatic leak-test report (hydro-test report to customer requirement) · certificate of conformity · packing list · operations & installation manual
Essem Works manufactures three distinct flexible-flow product families — each engineered for a fundamentally different function. Use this guide to identify the right product for your application.
A corrugated metal hose assembly is a thin-wall stainless steel tube formed into a precise annular (wave) corrugated profile that provides flexibility while maintaining full fluid and pressure containment. One or two layers of stainless steel wire braid are applied over the corrugated core to increase the working pressure rating and provide mechanical protection.
Compared with rubber hoses, corrugated metal hoses offer superior temperature range, full chemical resistance, zero permeation, fire safety, and significantly longer service life — the standard choice for industrial piping connections where vibration isolation, thermal flexibility, or movement compensation is required. Standard grades SS 304L · 316L held in stock; SS 321 to order.
MATERIALS SS 304L / 316L · AT 20 °C PRESSURES IN kg/cm² · ×0.98 = BAR TEST = 1.5× WP · BURST ≥ 4× WP
TABLE 1 — WORKING PRESSURE & MINIMUM BEND RADIUS
DN
Size
Working pressure (kg/cm²)
Min. bend radius (mm)
Hose only
Single braid
Double braid
Static
Flexing (T-2)
DN6
¼"
4
100
160
25
140
DN8
5/16"
4
100
160
32
165
DN10
⅜"
4
90
144
38
190
DN12
½"
3
80
128
45
210
DN16
⅝"
3
70
112
58
250
DN20
¾"
2
64
102
70
285
DN25
1"
2
50
80
85
325
DN32
1¼"
1.5
40
64
105
380
DN40
1½"
1.5
30
48
130
430
DN50
2"
1
28
44
160
490
DN65
2½"
1
24
38
200
580
DN80
3"
1
18
28
240
800
DN100
4"
0.8
16
26
290
1000
DN125
5"
0.6
12
20
350
1250
DN150
6"
0.6
10
16
400
1550
DN200
8"
0.5
8
12
520
2000
DN250
10"
0.25
6
9
620
2500
DN300
12"
0.2
4
6
720
3000
DN350 *
14"
0.1
2
4
900
3600
TABLE 2 — TEMPERATURE DERATING (× WP) · ISO 10380
Media temp.
304L
316L
321 †
−200 to −20 °C
1.00
1.00
1.00
20 °C
1.00
1.00
1.00
50 °C
0.87
0.88
0.92
100 °C
0.72
0.74
0.83
150 °C
0.65
0.67
0.78
200 °C
0.59
0.62
0.74
250 °C
0.55
0.58
0.71
300 °C
0.51
0.54
0.67
350 °C
0.48
0.52
0.64
400 °C
0.46
0.50
0.62
450 °C
0.45
0.48
0.61
500 °C
0.44
0.47
0.60
550 °C
0.43
0.47
0.59
Derating factors per ISO 10380:2012 Table 3 (proof-stress basis). Working pressure at temperature = the 20 °C rating of the weakest component × the factor for the grade. 304L / 316L standard continuous service −196 to +450 °C; above +450 °C on application. † SS 321 to order. Fittings & attachment can further limit ratings at temperature.
NOTES TO TABLE 1
1Ratings apply to complete braided assemblies with welded end fittings at ambient temperature; assembly-specific ratings are confirmed per order on the test certificate.
2Hose only (unbraided) is bulk hose for customer fabrication / low-pressure duty — limited by convolution squirm; never operate it at braided-assembly ratings.
3Static radius = permanently formed installation. Flexing radius = repeated / dynamic movement — use the STATIC column for a fixed, one-time installation and the FLEXING column for any repeated movement. Flexing radii shown are Type 2 (continuous / high-cycle movement); Type 1 radii for occasional, low-cycle movement are smaller — ask EWPL engineering.
4Pulsating / surge service: reduce working pressure by 50%. Values are EWPL published hose technical data. DN350 on request — confirm ratings with EWPL engineering.
Most metal-hose failures are installation-length failures. A hose that is too short over-bends at the fittings; one forced to absorb axial movement destroys its braid. These rules size the correct live length (Lv) — the flexible length between braid ferrules, excluding fittings.
1
Movement in one plane only
A braided hose absorbs movement perpendicular to its axis. Never apply axial compression / extension or torsion — for axial movement use an expansion bellows, or install the hose in a loop.
2
Lateral offset (both ends fixed)
Movement across the hose axis, T = total lateral travel; R = minimum bend radius (FLEXING column, p.08, for repeated movement; STATIC for one-time offset).
Lv = √( 6 · R · T + T² ) · Lp = √( Lv² − T² )
DN25 single-braid, repeated T = 25 mm · R (flexing) = 325 mm → Lv = √(6×325×25 + 25²) = √49,375 ≈ 222 mm → specify ≥ 225 mm live.
3
90° bend installation
Minimum live length for a 90° change of direction, plus straight tangents at each fitting:
Lv ≥ 1.57 × R
DN50 static 90° · R = 160 mm → Lv ≥ 252 mm → specify ≥ 255 mm. Flexing duty · R = 490 mm → Lv ≥ 770 mm.
LATERAL OFFSET — SCHEMATIC
4
Vibration duty
Install perpendicular to the main vibration direction, use the flexing-column radius, and keep the hose slack at operating position. Treat vibration amplitude as T. Clamp only rigid pipework — never the hose or braid.
5
Keep fittings out of the bend
Provide a straight tangent of at least 2 × hose OD after each fitting before any bend begins. Never let the bend start at the braid ferrule.
If in doubt, send us the movement, mounting orientation and available envelope with your STAMPED enquiry (p.18) — EWPL engineering will size the hose length for you.
—Corrugation damage — dents, corrosion pitting, media build-up
—Leakage or “sweating” at fittings and welds
—Permanent deformation — kinks, squirm (bulging convolutions), banana set
Replace any assembly showing these signs — never repair braided hose in the field.
RECOMMENDED INSPECTION INTERVAL
Annual
Static duty
6-monthly
Flexing, pulsating or corrosive duty
WHEN A HOSE COMES UP FOR REPLACEMENT
Every EWPL assembly is tagged and its test record retained — and we run an in-house laser marking machine, so permanent laser-etched serial marking can be specified on any order. Quote the tag or serial — an identical certified replacement ships from the stock-size programme in 24–48 hours.
An interlock hose (also called strip-wound hose) is constructed from a continuous stainless steel strip wound in a helix and locked together with an interlocking profile — unlike a corrugated hose which is formed from tube. The interlocked seam is open, so interlock hoses are not pressure-tight and are used as flexible protective conduits, armoured sleeves, exhaust ducting, and flow liners.
PRIMARY APPLICATIONS
PROTECTIVE SLEEVE / ARMOUR
INNER LINER IN CORRUGATED BORE
EXHAUST & VENTILATION DUCTING
PNEUMATIC CONVEYING
CABLE PROTECTION — HIGH-TEMP ZONES
FIG. 02 — STRIP-WOUND INTERLOCK PROFILE · MAX TEMP 700 °C (SS304) / 800 °C (SS321)
— CONSTRUCTION TYPES —
Double interlock
Overlapping strip sections create a robust, flexible structure with good axial strength. Most common type — preferred for protective sleeving and general conduit.
Loose interlock
Minimal strip engagement provides maximum bending flexibility. Used where the hose must conform to tight or irregular routing and axial load is low.
Polygonal interlock
Specialised cross-section providing torsional rigidity without sacrificing lateral flexibility — resists twisting while still bending freely.
— DIMENSIONAL SPECIFICATIONS · DN6 – DN200 —
DN
Bore (mm)
OD (mm)
C/L bend rad. (mm)
Max temp SS304 (°C)
DN6
6.0
8.0
38
700
DN8
8.0
10.0
38
700
DN10
10.0
12.5
50
700
DN12
12.0
15.0
50
700
DN16
16.0
19.0
50
700
DN20
20.0
23.5
120
700
DN25
25.0
28.5
135
700
DN32
32.0
35.0
135
700
DN40
40.0
43.5
165
700
DN50
50.0
53.5
178
700
DN65
65.0
68.0
245
700
DN80
80.0
83.0
280
700
DN100
100.0
105.0
555
700
DN125
125.0
130.0
590
700
DN150
150.0
155.0
655
700
DN200
200.0
207.0
1050
700
DOUBLE INTERLOCK, STANDARD SS304 · SS316L & SS321 TO ORDER · PROTECTIVE CONDUIT, NOT PRESSURE-RATED · PACKED INTERLOCK ≈ 2× RADIUS · SIZES ABOVE DN200 ON DEMAND — CONTACT ENGINEERING
A metal bellows expansion joint is a pressure-containing element incorporating one or more thin-wall corrugated bellows sections fabricated from stainless steel or special alloy. Installed in a pipeline, it absorbs thermal expansion and contraction, vibration, misalignment, and structural settlement — relieving connected equipment and pipe supports of potentially damaging forces and moments.
Unlike corrugated hoses, bellows and expansion joints are engineered-to-order products — each one calculated to the specific DN, pressure, temperature, and movement requirement of the installation, per EJMA and EN 14917:2021, with documented fatigue life, squirm stability analysis, and spring rate supplied with every order.
SIZE RANGE
DN50–DN3000
DESIGN STANDARD
EJMA / EN 14917
CONVOLUTION
SINGLE / MULTI-PLY
FIG. 03 — BELLOWS CONVOLUTION PROFILE
w HEIGHT · q PITCH · Lb ACTIVE LENGTH · nt TOTAL WALL THICKNESS
— CORE TECHNICAL SPECIFICATIONS —
Nominal diameter range
DN50 to DN3000
End fitting materials
Carbon steel, SS 304 / 316, precision-cast, forged alloy fittings
Connection types
Plain weld ends (ISO bevel) · EN 1092-1 flanges · ASME B16.5 flanges · RTJ
Design pressure
Full vacuum to 50 barg standard — higher pressures with engineering review
Temperature range
−196 °C to +900 °C (material-dependent)
Convolution construction
Single-ply or multi-ply laminated — superior fatigue and pressure performance
SELECT BY DIRECTION + MAGNITUDE OF MOVEMENT TO BE ABSORBED
Single bellows — axial
CFG. A
MOVEMENT
Axial compression / extension
THRUST
Not contained — anchors carry thrust
USE
Single-axis thermal expansion, anchored piping
Universal — dual bellows, lateral
CFG. B
MOVEMENT
Axial + lateral + angular
THRUST
Not contained — anchors required (tied variant: rods carry thrust)
USE
General purpose complex pipe movements
Hinged — single plane angular
CFG. C
MOVEMENT
Angular in one plane only
THRUST
Contained — via hinge apparatus
USE
In pairs / triples for large lateral offset
Gimbal — multi-plane angular
CFG. D
MOVEMENT
Angular in any plane
THRUST
Contained — via dual gimbal ring
USE
Omni-directional rotation at pipe bends
— RESTRAINED & PRESSURE-BALANCED —
Restrained — tie rods
CFG. E
Lateral · rods carry full thrust
Pressure-balanced (inline)
CFG. F
Axial + lateral · no main anchors
Pressure-balanced (elbow)
CFG. G
Axial + lateral at direction change
Internal liner (flow sleeve)
Fitted inside the bellows for high-velocity, turbulent or abrasive media — prevents impingement on the corrugated surface, extends fatigue life, smooths flow. Specify when gas or steam exceeds 1.2 m/s per 25 mm of bore up to DN150 (7.6 m/s above), liquid exceeds 0.6 m/s per 25 mm (3 m/s above), media is abrasive / particulate / slurry, flow is turbulent at direction changes, or for high-temperature steam and gas injection. Bellows only — corrugated-hose velocity limits are on p.09.
Dilute-cold 316L acceptable; hot → PTFE-lined or special alloy
Sulphuric acid
X
C
Only very dilute, cold; otherwise PTFE-lined or special alloy
Hydrochloric acid
X
X
PTFE-lined hose only
Chlorine — dry gas
C
C
Wet chlorine → X (PTFE-lined)
Milk · dairy · beverage
A
A
Sanitary tri-clamp, crevice-free welds
Vegetable oils · syrups
A
A
Important
Indicative only, at ambient temperature — corrosion depends on concentration, temperature, aeration, velocity and contamination. Final selection is confirmed by EWPL engineering against your STAMPED sheet (p.18); for aggressive or mixed media specify PTFE-lined hose or a special alloy (p.15).
COMPLETE ALL 7 BEFORE REQUESTING A QUOTATION — MORE DATA, FASTER RFQ
S
Size
Identify the required inner diameter (ID) precisely in DN or mm. Standard sizes: DN6–DN350 corrugated, DN6–DN200 interlock, DN50–DN3000 bellows. Oversizing reduces pressure ratings; undersizing increases flow velocity and pressure drop.
T
Temperature
State both the operating temperature of the media and the ambient external temperature. For steam or hot-oil service, specify maximum temperature including start-up peaks. For cryogenic service, specify minimum temperature and whether the hose will experience thermal cycling.
A
Application
Describe the installation: is the hose stationary or in motion? Specify direction of movement (axial, lateral, angular) and whether movement is static, intermittent, or continuous vibration. State spatial constraints and required free length.
M
Media
Identify every fluid or gas that will contact the hose bore — including cleaning agents and purge media. Also identify the external environment (condensation, chemical splash, UV, abrasion). Incompatible material–media combinations cause premature failure.
P
Pressure
State (a) normal working pressure, (b) maximum surge pressure, and (c) whether the system experiences pulsating pressure (cyclic variation). For pulsating service, working pressure must be reduced by 50% to account for fatigue.
E
End connections
Specify the required connection type at each end: thread standard (NPT / BSP / metric), flange standard (ASME B16.5 / EN 1092-1), bore size, and pressure class. Include whether rotation or swivel function is required.
D
Delivery / flow rate
State the volumetric flow rate or fluid velocity. For corrugated hoses, excessive velocity causes resonance and fatigue failure. Maximum recommended: gas 45 m/s, liquid 22 m/s (braided hose, straight run) — see Section 09 for bend and unbraided limits.
S · T · A · M · P · E · D — send the completed checklist to info@essemworks.com for a rapid, accurate quotation.
Working bar Surge / peak bar ☐ Pulsating Vacuum? ☐ Y☐ N mbar(a) Test pressure bar
EEnd connections
End 1 — type std size class End 2 — type std size class ☐ Swivel / rotation☐ O₂-clean☐ ATEX zone
DDelivery / flow
Flow rate (m³/h or kg/h) or velocity m/s
QAMaterial & QA
☐ 304L☐ 316L☐ 321☐ Other Fittings ☐ EN 10204 3.1☐ TPI witness☐ Helium leak test☐ Spring-rate report☐ Laser-etched serial marking
For bellows / expansion joints only
Design code ☐ EJMA☐ EN 14917☐ ASME Design life cycles Spring-rate limit N/mm Movement — axial ± mm lateral ± mm angular ± ° ☐ Internal liner☐ External cover Installation ☐ Between anchors☐ At equipment nozzle☐ Elbow / direction change
Our 32,000 sq.ft. manufacturing facility at Moraiya, Ahmedabad integrates hydroforming, mechanical forming, automated braiding, TIG welding, leak testing, and dispatch under one roof — every product moves through a controlled, traceable production flow.
1
2
3
4
5
6
Incoming material
Mill test certificates verified against specification · heat-number traceability begins.
Forming
Hydroforming DN20–DN300 · mechanical forming DN6–DN50 · dimensional checks at every setup, first-piece inspection.
Braiding
Single or double SS wire braid applied over the corrugated core on automated braiding machines.
Welding
TIG welding of end fittings · weld visual inspection and dimensional verification at each station.
Leak test
100% pneumatic leak test on every assembly · hydrostatic at 1.5× working pressure, burst and fatigue tests to customer requirement.
Dispatch
Full documentation pack — test records, certificates of conformity, packing list — marked, packed and dispatched.
Quality management system certified to ISO 9001:2015 by TÜV Rheinland — certified scope: stainless steel annular corrugated metallic hose, braid, hose assemblies and related end fittings. Environmental and occupational-health systems are certified to ISO 14001:2015 and ISO 45001:2018 across the full product range. Every product is traceable from raw material mill certificate through to final test record and dispatch documentation.
From a 6 mm instrument line to a DN3000 bellows — every EWPL assembly is engineered, pneumatically leak-tested and marked before dispatch. Send us your STAMPED specification or scan the QR for a quote.