"Food grade" in a stainless hose means four things: the grade is 316L, the end connections are hygienic — tri-clover or DIN — the welds are full-penetration and crevice-free, and the assembly is built and packed so that it arrives clean. It does not mean a corrugated hose is the right product for every line in a food plant, and this page says where it is and where it is not.
Where a stainless hose belongs in a food plant
- Steam — culinary steam to cookers, retorts, kettles and sterilisers, and steam to the CIP heat exchanger. This is the largest food-industry duty we supply, and it is a derating question before it is anything else.
- CIP and SIP loops — hot caustic and acid on the clean cycle, steam on the sterilise cycle, at temperatures a polymer hose ages under. See autoclave and SIP hose and caustic hose.
- Sanitary product transfer where flexibility is needed at a pump, a filler or a tank connection and the product tolerates a corrugated bore — syrups, oils, brewery wort and beer, dairy CIP returns.
- Brewery and beverage — CO₂, glycol, hot water and product at the brewhouse and the filler.
- Water for injection and high-purity duty in the pharmaceutical plant next door, to the same construction with tighter finish requirements.
How a food-grade assembly is built
Annular corrugated tube and braid in 316L; tri-clamp (tri-clover) ferrules to ISO 2852 / DIN 32676, DIN 11851 unions or ISO 2037 tube ends, welded with full penetration and no crevice at the root; the braid captured outside the wetted path. Sizes DN6 to DN350 with the ratings at 20 °C on the braided corrugated hose page and the derating for steam on the derating page. Assemblies are pneumatically leak-tested; a hydrostatic test to 1.5 × working pressure with water is available on request, drained, capped and packed clean; mill certificates to EN 10204 3.1 on request.
Where a corrugated hose is not the right product
A corrugated bore is not a smooth bore. Product sits in the convolutions, and a line that has to be verifiably clean between products — allergen changeovers, high-viscosity product, anything with particulates that lodge — is better served by a smooth-bore product than by a stainless corrugated hose, however good the welds. We would rather say so at enquiry than supply an assembly that fails an audit. For those lines a PTFE-lined assembly — smooth PTFE liner, stainless braid outside — is often the right answer: the liner gives the cleanability and the chemical inertness, the braid gives the pressure rating. Where the product line simply needs flexibility at a filler and the product is clean-in-place, the corrugated hose is fine and considerably more robust.
Documentation the auditor asks for
Material certificates for the tube, braid and ferrules to EN 10204 3.1, showing the heat and the grade; the leak-test report for each assembly (hydrostatic test certificate where the order calls for it); a declaration of the wetted materials; and, where the plant requires it, a statement of surface finish for the ferrules. We do not claim food-contact approvals we do not hold — the wetted materials are 316L stainless and, in PTFE-lined assemblies, PTFE, and the certificates say so.
What to send with an enquiry
Bore, medium, pressure, temperature, movement and both end connections. The reasoning for each is on how to specify an assembly. A drawing or a photograph of the existing hose shortens the exchange.
Related technical reading
Media compatibility · Temperature derating · Stainless grades · Food and beverage industry
Questions we are asked
Is corrugated stainless hose suitable for direct product contact?
For clean-in-place product lines where flexibility is needed at a pump or filler, yes, in 316L with hygienic ends. For lines that must be verifiably clean between products or carry particulates, a smooth-bore PTFE-lined assembly is usually the better product, and we will say so at enquiry.
Which end connections do you fit?
Tri-clamp (tri-clover) ferrules to ISO 2852 / DIN 32676, DIN 11851 unions, ISO 2037 tube ends, or any other standard end, welded with full penetration and no crevice at the root.
Can the same hose carry culinary steam?
Yes — steam is the largest food-plant duty we supply. Size from the derated rating at the steam temperature, not the 20 °C figure; the steam hose page and the derating page set it out.
What documentation comes with a food-grade assembly?
Material certificates to EN 10204 3.1 for tube, braid and ferrules on request, the leak-test report for each assembly (hydrostatic test certificate where the order calls for it), and a declaration of wetted materials. We do not claim approvals we do not hold.
Related
SS Braided Corrugated Hose
DN6 to DN350 — construction, the full table, materials and standards.
View →PTFE-Lined Assemblies
Smooth bore, chemically inert, stainless braid outside — for the lines a corrugated bore does not suit.
View →Food & Beverage
The duties in the plant and the products that suit them.
View →